In fact, the glass lined reactor generally has no problem and has a long service life. However, because it is lined with high silicon glass on the inner surface of the steel container, it becomes a composite product after being fired at high temperature and firmly attached to the metal surface. Therefore, it has the advantages of good corrosion resistance, but also has the defect of surface brittleness. However, due to the vibration impact and other composite forces during the operation of the glass lined reactor, the metal parts will have a "hard to hard" relationship. With the extension of time, the local impact deformation becomes permanent deformation, the recovery stress decreases, forming gaps, and finally leading to the wear of parts with low hardness.
The most common are transmission parts (bearing chamber) wear, local surface damage, reactor inlet wear, reactor outlet wear, local reactor wall damage, reactor inlet hole damage, connector damage, etc.